Page 89 - Andersen Architectural Collection E-Series 2017-18 Product Guide for Professionals
P. 89
3 WIDE 10° CASEMENT BOW
4 WIDE 10° CASEMENT BOW
Frame
Expander
Frame
Expander
Rough Opening Height
Unit Height
Unit Height
D
D Rough Opening Height
Frame
Expander
Frame
Expander 6 WIDE 10° CASEMENT BOW
4 9/16"
B
5 WIDE 10° CASEMENT BOW
C 4 9/16" ROUGH OPENING
4-Wide 10˚ Casement Bow Windows
B 3-Wide 10˚ Casement Bow Windows ROUGH OPENING
C
E (Rough Opening) E (Rough Opening) ROUGH OPENING ROUGH OPENING
Frame
F (Overall Unit Width) Frame F (Overall Unit Width)
Expander
Expander
4 9/16" 4 9/16" 4 9/16" 4 9/16"
Unit Height Rough Opening Height 80° 75°
UNIT
Unit Width Unit Width Unit Width Unit Height Rough Opening Height Unit Width UNIT
Unit Width D Unit Width Unit Width WIDTH EXTERIOR INSTALLATION WIDTH EXTERIOR
INSTALLATION
FLANGE
FLANGE
MULL COVER
D
MULL COVER
A A 10° 10°
Frame Horizontal Section Horizontal Section
Expander Frame
Expander
4 9/16"
Unit Rough Opening Unit Number Wall A B C D E
E
C
D
B
Unit Rough Opening
Height Height (Ft.-In.) Width of Units Thickness Angle Projection Projection B Seating Depth Rough Opening Unit Number Wall A 5-Wide 10˚ Casement Bow Windows 6-Wide 10˚ Casement Bow Windows
4 9/16"
(Ft.-In.)
Width (Ft.-In.)
Wide (inches) (Ft.-In.) (Ft.-In.) Height Height (Ft.-In.) Width of Units Thickness Angle Projection Projection Seating Depth Rough Opening
B
3-0 3-0 1/2 1-5 3/4 3 4 9/16 10° 0-3 5/32 0-7 23/32 C 0-4 21/32 4-6 3/16 Wide (inches) (Ft.-In.) (Ft.-In.) (Ft.-In.) Width (Ft.-In.)
3-0
3-4 3-4 1/2 1-8 3 4 9/16 10° 0-3 9/16 0-8 1/8 0-5 1/16 3-0 1/2 5-0 7/8 1-5 3/4 4 4 9/16 10° 0-6 1/4C 0-10 13/16 0-7 3/4 5-11 5/8
6-8 1/2
0-5 3/4
4-0 4-0 1/2 2-0 3 4 9/16 10° 0-4 1/4 F (Overall Unit Width) 3-4 3-4 1/2 6-0 3/4 1-8 4 4 9/16 10° 0-7 1/32 0-11 19/32 0-8 17/32 ROUGH OPENING ROUGH OPENING
0-8 13/16
10°
0-8 13/32
4-6 4-6 1/2 2-4 3 4 9/16 10° 0-4 15/16 E (Rough Opening Width) 4-0 4-0 1/2 7-0 5/8 2-0 4 4 9/16 Rough Opening Width 1-1 0-9 29/32 8-0 3/16
0-9 1/2
0-6 13/32
4-6
5-0 5-0 1/2 2-6 3 4 9/16 10° 0-5 5/16 0-9 7/8 0-6 13/16 4-6 1/2 7-6 9/16 2-4 4 4 9/16 10° 0-9 13/16 1-2 3/8 0-11 5/32 9-3 7/8
5-6 5-6 1/2 5-0 5-0 1/2 2-6 4 4 9/16 10° 0-10 1/2 1-3 1/16 1-0 9-11 11/16
6-0 6-0 1/2 4 9/16" 4 9/16" 5-6 5-6 1/2 4 9/16" 4 9/16"
6-0
6-0 1/2
70° 65° Bay & Bow Windows
Unit Width INSTALLATION WIDTH Unit Width INSTALLATION WIDTH E-Series
UNIT
UNIT
Unit Width
Unit Width
FLANGE
FLANGE
Unit Width Unit Width EXTERIOR
Unit Width Unit Width Unit Width MULL COVER EXTERIOR
MULL COVER
Unit Width Unit Width 10° 10°
A A
Horizontal Section Horizontal Section
Unit Rough Opening Unit Number Wall A B C D E
30˚ Casement Angle Bay Windows
Height Height (Ft.-In.) Width of Units Thickness Angle Projection Projection Seating Depth Rough Opening
E (inches)
Unit Rough Opening Unit Number Wall A B C D Wide (Ft.-In.) (Ft.-In.) (Ft.-In.) Width (Ft.-In.)
6
3-0 1/2
1-5 3/4
Height Height (Ft.-In.) Width of Units Thickness Angle Projection 3-0 Projection Seating Depth Rough Opening 4 9/16 10° 1-1 15/16 1-6 1/2 1-3 7/16 8-8 3/4
Wide (inches) (Ft.-In.) 3-4 (Ft.-In.) (Ft.-In.) 1-8 Width (Ft.-In.) 4 9/16 10° 1-3 21/32 1-8 7/32 1-5 5/32 9-9 11/16
3-4 1/2
6
3-0 3-0 1/2 1-5 3/4 5 4 9/16 10° 0-9 11/32 4-0 1-1 29/32 0-10 27/32 2-0 7-4 9/16 4 9/16 10° 1-6 3/4 1-11 5/16 1-8 1/4 11-8 5/8
4-0 1/2
6
3-4 3-4 1/2 1-8 5 4 9/16 10° 0-10 1/2 1-3 1/16 1-0 8-3 7/16
4-6 4-6 1/2
4-0 4-0 1/2 2-0 5 4 9/16 10° 1-0 9/16 5-0 1-5 1/8 1-2 1/16 9-10 7/8 EXTENSION JAMB
5-0 1/2
4-6 4-6 1/2 2-4 5 4 9/16 10° 1-2 5/8 5-6 1-7 3/16 1-4 1/8 11-6 1/4 4 9 /16"
5-6 1/2
5-0 5-0 1/2 2-6 5 4 9/16 10° 1-3 21/32 6-0 1-8 7/32 1-5 5/32 12-3 15/16 INTERIOR
6-0 1/2
5-6 5-6 1/2 MULL CASING
6-0 6-0 1/2
ANGLE BAY
ENCLOSURE UNIT WIDTH
EXTERIOR
MULL COVER UNIT WIDTH 30 O
Horizontal Section
Shown with ovolo (colonial) glass stops.
PROPER INSTALLATION AND MAINTENANCE OF E-SERIES PRODUCTS IS ESSENTIAL TO ATTAIN OPTIMUM PERFORMANCE AND OPERATION. 87
WRITTEN INSTALLATION INSTRUCTIONS THAT PROVIDE GUIDELINES FOR PROPER INSTALLATION ARE AVAILABLE BY VISITING ANDERSENWINDOWS.COM.
CUSTOM SIZES ARE AVAILABLE. CONTACT YOUR LOCAL SUPPLIER FOR MORE INFORMATION. DRAWINGS ARE NOT TO SCALE.