Page 86 - Andersen Architectural Collection E-Series 2017-18 Product Guide for Professionals
P. 86

10˚ Casement Bow Window Sizes






                                     WIDTH                            NOTES
                                                                      Projection is measured from the outside of the exterior
                                                                      sheathing to the exterior sheathing line of the
                            3-WIDE     4-WIDE     5-WIDE    6-WIDE
                 Rough Opg.  4'-6 3/16"  5'-11 5/8"  7'-4 9/16"  8'-8 3/4"  outermost unit.
               3'-0 1/2"   15 3/4 30-3  15 3/4 30-4  15 3/4 30-5  15 3/4 30-6  Support is required underneath all bay and bow units.
               3'-4 1/2"   15 3/4 34-3  15 3/4 34-4  15 3/4 34-5  15 3/4 34-6  For additional support, we offer a cable support
               4'-0 1/2"   15 3/4 40-3  15 3/4 40-4  15 3/4 40-5  15 3/4 40-6  system.
               4'-6 1/2"   15 3/4 46-3  15 3/4 46-4  15 3/4 46-5  15 3/4 46-6  Insulated platforms and brackets are not included.
               5'-0 1/2"   15 3/4 50-3  15 3/4 50-4  15 3/4 50-5  15 3/4 50-6
               5'-6 1/2"   15 3/4 56-3  15 3/4 56-4  15 3/4 56-5  15 3/4 56-6
               6'-0 1/2"   15 3/4 60-3  15 3/4 60-4  15 3/4 60-5  15 3/4 60-6
                Projection  0'-3 5/32"  0'-6 1/4"  0'-9 11/32"  1'-1 15/16"

                 Rough Opg.  5'-0 7/8"  6'-8 1/2"  8'-3 7/16"  9'-9 11/16"
               3'-0 1/2"    1830-3     1830-4     1830-5     1830-6
               3'-4 1/2"    1834-3     1834-4     1834-5     1834-6
               4'-0 1/2"    1840-3     1840-4     1840-5     1840-6
               4'-6 1/2"    1846-3     1846-4     1846-5     1846-6
               5'-0 1/2"    1850-3     1850-4     1850-5     1850-6
               5'-6 1/2"    1856-3     1856-4     1856-5     1856-6
               6'-0 1/2"    1860-3     1860-4     1860-5     1860-6
                Projection  0'-3 9/16"  0'-7 1/32"  0'-10 1/2"  1'-3 21/32"


                 Rough Opg.  6'-0 3/4"  8'-0 3/16"  9'-10 7/8"  11'-8 5/8"
               3'-0 1/2"    2030-3     2030-4     2030-5     2030-6
               3'-4 1/2"    2034-3     2034-4     2034-5     2034-6
          HEIGHT  4'-0 1/2"  2040-3    2040-4     2040-5     2040-6
                                                  2046-5
                                       2046-4
               4'-6 1/2"
                                                             2046-6
                            2046-3
               5'-0 1/2"    2050-3     2050-4     2050-5     2050-6
               5'-6 1/2"    2056-3     2056-4     2056-5     2056-6
               6'-0 1/2"    2060-3     2060-4     2060-5     2060-6
                Projection  0'-4 1/4"  0'-8 13/32"  1'-0 9/16"  1'-6 3/4"
                 Rough Opg.  7'-0 5/8"  9'-3 7/8"  11'-6 1/4"
               3'-0 1/2"    2430-3     2430-4     2430-5     -----
               3'-4 1/2"    2434-3     2434-4     2434-5     -----
               4'-0 1/2"    2440-3     2440-4     2440-5     -----
               4'-6 1/2"    2446-3     2446-4     2446-5     -----
               5'-0 1/2"    2450-3     2450-4     2450-5     -----
               5'-6 1/2"    2456-3     2456-4     2456-5     -----
               6'-0 1/2"    2460-3     2460-4     2460-5     -----
                Projection  0'-4 15/16"  0'-9 13/16"  1'-2 5/8"  -----


                 Rough Opg.  7'-6 9/16"  9'-11 11/16"  12'-3 15/16"
               3'-0 1/2"    2630-3     2630-4     2630-5     -----
               3'-4 1/2"    2634-3     2634-4     2634-5     -----
               4'-0 1/2"    2640-3     2640-4     2640-5     -----
               4'-6 1/2"    2646-3     2646-4     2646-5     -----
               5'-0 1/2"    2650-3     2650-4     2650-5     -----
               5'-6 1/2"    2656-3     2656-4     2656-5     -----
               6'-0 1/2"    2660-3     2660-4     2660-5     -----
                Projection  0'-5 5/16"  0'-10 1/2"  1'-3 21/32"  -----








        84         FOR WINDOWS OVER 30 SQUARE FEET OR RATED HIGHER THAN PG50, ONE OF THESE THREE INSTALLATION METHODS IS REQUIRED:
                                A) THROUGH THE JAMB B) ALUMINUM NAILING FLANGE OR C) INSTALLATION CLIPS.
                 ADDITIONAL CUSTOM SIZES ARE AVAILABLE. CONTACT YOUR LOCAL SUPPLIER FOR MORE INFORMATION. DRAWINGS ARE NOT TO SCALE.
   81   82   83   84   85   86   87   88   89   90   91