Page 215 - Andersen Architectural Collection A-Series 2018-19 Product Guide for Professionals
P. 215
A
A
B
B
TECHNICAL DATA
C C
2-Way LVL Joining
®
A-Series: Frenchwood Gliding, Inswing and Outswing Patio Doors, Frenchwood Patio Door Sidelights and Transoms
(A + B) ÷ 2 = 10'-0" (3048) 57 42 A B A B A B
4 / " (A + B) ÷ 2 = 9'-6" (2896) 60 45
9
16
LVL (A + B) ÷ 2 = 9'-0" (2743) 63 47 41 C C C
Average Adjacent Door/Transom/Sidelight Dimension (A + B) ÷ 2 = 7'-0" (2134) 80 60 49 41 41 40 A B C Note: When joining
50
67
(A + B) ÷ 2 = 8'-6" (2591)
(A + B) ÷ 2 = 8'-0" (2438)
52
43
71
76
57
46
(A + B) ÷ 2 = 7'-6" (2286)
53
80
65
(A + B) ÷ 2 = 6'-6" (1981)
57
70
(A + B) ÷ 2 = 6'-0" (1829)
44
80
hinged inswing or
77
63
80
49
(A + B) ÷ 2 = 5'-6" (1676)
outswing patio doors,
do not join hinge
53
(A + B) ÷ 2 = 5'-0" (1524)
80
80
45
68
jamb to hinge jamb.
80
60
50
77
80
(A + B) ÷ 2 = 4'-6" (1372)
66
(A + B) ÷ 2 = 4'-0" (1219)
80
80
55
80
52
80
65
80
77
(A + B) ÷ 2 = 3'-6" (1067)
80
59
80
73
80
80
(A + B) ÷ 2 = 3'-0" (914)
50
3 "
"
9
LVL Joining Material
51
80
62
80
72
80
80
80
(A + B) ÷ 2 = 2'-6" (762) 80 PSF 44 44 41 45 4 / 16 (116) x / 4 (19)
(A + B) ÷ 2 = 2'-0" (610) 80 80 80 80 80 80 75 61 53 45
(A + B) ÷ 2 = 1'-6" (457) 80 80 80 80 80 80 80 80 74 62
C = (length of join) 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0"
(1676) (1829) (1981) (2134) (2286) (2438) (2591) (2286) (2438) (2591)
2-Way LVL Joining
A-Series: Frenchwood Gliding, Inswing and Outswing Patio Doors, Frenchwood Patio Door Sidelights and Transoms
®
(A + B) ÷ 2 = 10'-0" (3048) 80 80 79 61 52 41 A B A B A A B B
6 / " 80 80 80 65 55 44
9
16
LVL (A + B) ÷ 2 = 9'-6" (2896)
(A + B) ÷ 2 = 9'-0" (2743) 80 80 80 68 57 46
(A + B) ÷ 2 = 8'-6" (2591) 80 80 80 73 61 49 42
C C C C
(A + B) ÷ 2 = 8'-0" (2438) 80 80 80 76 64 51 44 41 A A B B
Average Adjacent Door/Transom/Sidelight Dimension (A + B) ÷ 2 = 6'-6" (1981) 80 PSF 64 55 45 42 42 C C
80
80
48
80
69
55
80
(A + B) ÷ 2 = 7'-6" (2286)
50
73
80
80
80
80
59
(A + B) ÷ 2 = 7'-0" (2134)
80
80
80
80
80
68
48
80
59
80
80
80
(A + B) ÷ 2 = 6'-0" (1829)
80
53
80
65
80
80
76
47
80
(A + B) ÷ 2 = 5'-6" (1676)
80
80
80
80
58
50
80
70
80
(A + B) ÷ 2 = 5'-0" (1524)
57
48
65
79
80
80
80
80
80
80
(A + B) ÷ 2 = 4'-6" (1372)
52
72
80
80
63
80
80
80
80
80
(A + B) ÷ 2 = 4'-0" (1219)
80
80
80
73
80
80
80
80
80
61
(A + B) ÷ 2 = 3'-6" (1067)
Note: When joining
80
80
69
80
80
80
80
80
80
80
(A + B) ÷ 2 = 3'-0" (914)
hinged inswing or
outswing patio doors,
80
80
80
80
80
80
80
80
80
80
(A + B) ÷ 2 = 2'-6" (762)
do not join hinge
jamb to hinge jamb.
(A + B) ÷ 2 = 2'-0" (610) 80 80 80 80 80 80 80 80 80 80
(A + B) ÷ 2 = 1'-6" (457) 80 80 80 80 80 80 80 80 80 80
C = (length of join) 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 6 / 16 (167) x / 4 (19)
9
"
3 "
(1676) (1829) (1981) (2134) (2286) (2438) (2591) (2286) (2438) (2591) LVL Joining Material
• Two-panel doors shown. Three- and four-panel doors similar with different overall A and B widths.
• Numerical values in charts represent structural performance only.
• Dimensions in parentheses are in millimeters.
• Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination.
®
• Andersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. Combination Designs, Product Performance
213 & Installation