Page 213 - Andersen Architectural Collection A-Series 2018-19 Product Guide for Professionals
P. 213
TECHNICAL DATA
2-Way LVL Joining
A-Series: Factory-Joined Specialty Windows
(A + B) ÷ 2 = 6'-6" (1981) 42 31
4 / " (A + B) ÷ 2 = 6'-0" (1829) 45 33
9
16
Average Adjacent Window Dimension (A + B) ÷ 2 = 4'-6" (1372) 61 PSF A B
LVL (A + B) ÷ 2 = 5'-6" (1676) 50 37 30 C
54
40
32
(A + B) ÷ 2 = 5'-0" (1524)
45
37
31
67
40
49
(A + B) ÷ 2 = 4'-0" (1219)
70
36
31
58
47
(A + B) ÷ 2 = 3'-6" (1067)
35
70
54
65
41
(A + B) ÷ 2 = 3'-0" (914)
(A + B) ÷ 2 = 2'-6" (762)
70
52
70
61
70
41
(A + B) ÷ 2 = 2'-0" (610)
70
70
57
49
70
70
70
(A + B) ÷ 2 = 1'-6" (457) 70 70 66 51 43 34 35 40 35
C = (length of join) 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 9 " 3 "
(1676) (1829) (1981) (2134) (2286) (2438) (2591) (2286) (2438) 4 / 16 (116) x / 4 (19)
LVL Joining Material
2-Way LVL Joining
A-Series: Factory-Joined Specialty Windows
(A + B) ÷ 2 = 10'-0" (3048) 69 49 40 31
6 / " (A + B) ÷ 2 = 9'-6" (2896) 70 52 42 33
9
16
LVL (A + B) ÷ 2 = 9'-0" (2743) 70 54 44 34 C
(A + B) ÷ 2 = 8'-6" (2591) 70 58 47 37 31
(A + B) ÷ 2 = 8'-0" (2438) 70 61 50 38 32 A B
Average Adjacent Window Dimension (A + B) ÷ 2 = 6'-6" (1981) 70 70 62 48 40 32 30
35
65
54
41
70
(A + B) ÷ 2 = 7'-6" (2286)
37
(A + B) ÷ 2 = 7'-0" (2134)
44
69
70
57
51
66
34
43
70
(A + B) ÷ 2 = 6'-0" (1829)
70
70
38
48
33
70
70
56
(A + B) ÷ 2 = 5'-6" (1676)
35
61
(A + B) ÷ 2 = 5'-0" (1524)
51
70
41
70
70
69
70
70
58
(A + B) ÷ 2 = 4'-6" (1372)
64
70
36
44
51
70
70
70
(A + B) ÷ 2 = 4'-0" (1219)
9
3 "
"
LVL Joining Material
37
42
59
70
51
70
70
70
70
(A + B) ÷ 2 = 3'-6" (1067) 70 PSF 46 40 33 32 31 6 / 16 (167) x / 4 (19)
(A + B) ÷ 2 = 3'-0" (914) 70 70 70 70 70 67 58 48 42 35
(A + B) ÷ 2 = 2'-6" (762) 70 70 70 70 70 80 71 59 51 43
(A + B) ÷ 2 = 2'-0" (610) 70 70 70 70 70 80 80 70 62 52
(A + B) ÷ 2 = 1'-6" (457) 70 70 70 70 70 80 80 80 70 70
C = (length of join) 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0"
(1676) (1829) (1981) (2134) (2286) (2438) (2591) (2286) (2438) (2591)
Combination Designs, & Installation
• Numerical values in charts represent structural performance only.
• Dimensions in parentheses are in millimeters.
• Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination.
• Andersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com. Product Performance
®
211