Page 212 - Andersen Architectural Collection A-Series 2018-19 Product Guide for Professionals
P. 212
COMBINATION DESIGNS
1-Way LVL Joining
A-Series: Factory-Joined Specialty Windows
(A + B) ÷ 2 = 10'-0" (3048) 70 70 70 55 44 33
4 / " (A + B) ÷ 2 = 9'-6" (2896) 70 70 70 55 44 33 C
9
16
LVL (A + B) ÷ 2 = 9'-0" (2743) 70 70 70 55 44 33
A B
(A + B) ÷ 2 = 8'-6" (2591) 70 70 70 55 44 33
(A + B) ÷ 2 = 8'-0" (2438) 70 70 70 55 44 33
Average Adjacent Window Dimension (A + B) ÷ 2 = 6'-6" (1981) 70 70 70 56 45 34 30 4 / 16 (116) x / 4 (19)
33
70
70
44
70
55
(A + B) ÷ 2 = 7'-6" (2286)
44
70
55
33
70
70
(A + B) ÷ 2 = 7'-0" (2134)
56
70
35
70
70
45
(A + B) ÷ 2 = 6'-0" (1829)
9
"
3 "
70
70
70
58
36
47
(A + B) ÷ 2 = 5'-6" (1676)
LVL Joining Material
70
49
70
38
32
70
60
(A + B) ÷ 2 = 5'-0" (1524)
52
70
70
64
(A + B) ÷ 2 = 4'-6" (1372)
36
70
70
67
43
55
70
(A + B) ÷ 2 = 4'-0" (1219)
70
70
70
70
61
48
41
(A + B) ÷ 2 = 3'-6" (1067) 70 PSF 40 34 33
(A + B) ÷ 2 = 3'-0" (914) 70 70 70 70 67 53 45 36 31
(A + B) ÷ 2 = 2'-6" (762) 70 70 70 70 70 62 53 43 37 31
(A + B) ÷ 2 = 2'-0" (610) 70 70 70 70 70 70 62 50 44 36
(A + B) ÷ 2 = 1'-6" (457) 70 70 70 70 70 70 70 67 59 49
C = (length of join) 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0"
(1676) (1829) (1981) (2134) (2286) (2438) (2591) (2286) (2438) (2591)
1-Way LVL Joining
A-Series: Factory-Joined Specialty Windows
(A + B) ÷ 2 = 10'-0" (3048) 70 70 70 70 70 66 54 42 35
9
6 / " (A + B) ÷ 2 = 9'-6" (2896) 70 70 70 70 70 66 54 42 35 C
16
LVL (A + B) ÷ 2 = 9'-0" (2743) 70 70 70 70 70 66 54 42 35
A B
(A + B) ÷ 2 = 8'-6" (2591) 70 70 70 70 70 66 54 42 35
(A + B) ÷ 2 = 8'-0" (2438) 70 70 70 70 70 66 54 42 36
Average Adjacent Window Dimension (A + B) ÷ 2 = 6'-6" (1981) 70 70 70 70 70 69 57 45 39 6 / 16 (167) x / 4 (19)
70
70
70
43
36
55
70
67
70
(A + B) ÷ 2 = 7'-6" (2286)
70
70
70
70
44
37
56
70
67
(A + B) ÷ 2 = 7'-0" (2134)
70
59
70
70
70
70
47
40
70
(A + B) ÷ 2 = 6'-0" (1829)
70
70
42
70
49
62
70
70
70
(A + B) ÷ 2 = 5'-6" (1676)
3 "
"
9
70
44
70
70
52
65
70
70
70
(A + B) ÷ 2 = 5'-0" (1524)
LVL Joining Material
70
70
70
70
(A + B) ÷ 2 = 4'-6" (1372)
70
70
42
70
60
52
70
70
70
70
(A + B) ÷ 2 = 4'-0" (1219)
58
70
67
70
70
70
(A + B) ÷ 2 = 3'-6" (1067) 70 PSF 70 70 56 48 40
70
70
48
70
(A + B) ÷ 2 = 3'-0" (914) 70 70 70 70 70 70 70 70 64 53
(A + B) ÷ 2 = 2'-6" (762) 70 70 70 70 70 70 70 70 70 63
(A + B) ÷ 2 = 2'-0" (610) 70 70 70 70 70 70 70 70 70 70
(A + B) ÷ 2 = 1'-6" (457) 70 70 70 70 70 70 70 70 70 70
C = (length of join) 5'-6" 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0"
(1676) (1829) (1981) (2134) (2286) (2438) (2591) (2286) (2438) (2591)
• Numerical values in charts represent structural performance only.
• Dimensions in parentheses are in millimeters.
• Structural performance of any combination is only as high as the lowest structural performance of any individual unit or joining material in the combination.
®
• Andersen products must be installed and anchored properly according to joining and installation guides to meet rated structural performance. Refer to product joining and installation guides at andersenwindows.com.