TECHNICAL DATA




           GENERAL NOTES                        to, all building materials used in the window and patio door   materials or devices are applied to or used in conjunction
           When ordering, make certain you specify, then verify, the exact   area. Proper sealant joint design is based upon the expected   with Andersen products.
           product, unit dimensions, configuration requirements, color and   movement of adjacent materials and the movement capability     3. In wall construction utilizing brick facades, leave adequate
           options you desire on each window or patio door. Before   of the sealant. A general rule of thumb is that the depth of    clearance between sill, jambs and brick for sealing and
           installing the product, we suggest you verify that it includes the   the sealant joint should be equal to half the width (D= W/2),   dimensional change of framework.
                                                                          1
           features and options you ordered. Visit andersenwindows.com    but generally not less than  ⁄4" (6) or more than  ⁄2" (13).   4. Acid solutions commonly used to wash brick and other
                                                              1
           for product installation and joining guides. Printing limitations   Foam-plastic backer rod can be used to limit the depth          masonry materials will damage glass, fasteners, hardware
           prohibit exact color duplication of products. View actual     of the sealant joint, to provide a backstop for tooling the   and metal flashing. Protect unit and follow cleaning product
           samples for building specifications. Andersen Corporation   sealant without damage to the bond. It also acts as a bond   instructions carefully. Damage caused by acid solution is not
           reserves the right to change details, specifications or sizes   breaker to help minimize stress in the sealant. Sealants   covered under the Andersen limited warranty.
           without notice. The customer assumes all risk of alterations    should be maintained seasonally and repaired and/or   5. Andersen windows may be combined in ribbons or stacks
           made to Andersen ®  products.        replaced as needed.                 if each unit is positively secured to structural elements on
                                                                                    opposing sides and if the proper joining system is used.
           CODES                                GENERAL INSTALLATION GUIDELINES     See page 89 for more information.
           Appropriate selection of Andersen products that conform to       1.  Read and follow the installation guide in its entirety.
           all applicable laws, ordinances, building codes and safety   2.  Decide whether you are integrating to a surface barrier or a   SAFETY GLASS
           requirements is the sole responsibility of the architect,       membrane drainage system before installing the product.   Unless specifically ordered, Andersen   windows are not
           designer, building owner and/or contractor. Check with your     The appropriate method for your installation may vary based  made with safety glass and, if broken, the glass could
           local building code officials for specific information. Unit wind   on building design, application and industry practices.  fragment, causing injury. Andersen windows may be
           load, performance grade and energy performance information      3.  Make certain the drainage plane is continuous (proper   ordered with tempered glass which may reduce the
           is provided on pages 89-95. For up-to-date product     overlaps to shed water, taped seams, etc.).  likelihood of injury when broken. All Andersen patio doors
           performance information, visit andersenwindows.com. The   4.  Andersen products should be installed only in the vertical   are made with tempered glass. Differences in appearance
           performance of any building system depends on the design and   position.  between tempered and non-tempered glass can be
           construction of the building system in its entirety, which should   5.  Check the rough opening to make sure it is sized properly,   expected. Slight visual distortions may be noticeable
           meet building code requirements, as well as address product    is square and is level.  and occur normally as a result of the tempering process.
           and material limitations and local environment and climate.  6.  Install the window plumb.  Building codes require safety glass in locations adjacent
                                                7.  Install the window level.       to or near doors and other locations.
           DRIP CAPS                            8.  Install the window square. Diagonal measurements should
           Drip caps are a specific type of flashing or trim that is used at   be within  ⁄ 8" (3).  WINDOW AND PATIO DOOR SAFETY
                                                       1
           the head of a window or door to direct water from the drainage   9.   Follow installation instructions to properly locate shims and   Windows may provide a secondary avenue of escape or
           plane out beyond the face of the unit.  to make sure that units are plumb, level and square. Shims   rescue in an emergency, such as a fire. Every family should
                                                  are always required under the window jambs at the sill and   develop an escape plan and make sure family members
           FLASHING                               along the jambs on the sides.     know how to escape from the home in an emergency. In
           Flashing is an important element in a building’s water   10. Check for squareness of unit before final anchoring of the   your plan, include two ways to escape from every room in
           management system. It is used to shed and direct water to         product into the wall.  case one way is blocked by fire or smoke, and make sure
           the building exterior or to the drainage plane. Flashing materials   11. Anchor window as directed with appropriate fasteners.  you have a designated meeting place outside. A window          Combination Designs,   Product Performance,   Installation & Warranty
           are typically applied starting from the bottom and working    12.  Integrate the window into the drainage plane of the wall   or a door is an alternate means of escape or rescue.
           upward, with each successive layer overlapping the previous       using quality flashing and sealing materials. All flashing   Practice your plan until each member of the family
           one in shingle fashion. Water infiltration problems in any type    materials should be properly overlapped to shed water.  understands it and is able to escape without assistance.
           of building can be reduced by properly flashing and/or sealing   13. Allow  ⁄ 4" (6) minimum space for a sealant joint around   Remember, you may not be able to reach children during
                                                     1
           around all building openings, including windows and doors.  perimeter of unit between exterior finish materials and unit.  a fire emergency. Teach children – even very young
                                                14. Insulate and seal the interior cavity between the window   children – that they must escape from a fire in the home
           USE OF SHIMS                           frame and the rough opening.      and never hide from the fire or from emergency personnel.
           Shims are often used along the side jambs of windows and doors    15. Check unit operation before application of interior trim.
                                                                                               ®
           to center the unit in the rough opening and to position it plumb,        LOOKOUT FOR KIDS  PROGRAM
           level and square. In addition, shims are always required for     EXTERIOR PAINTING/SEALING OF ANDERSEN  PRODUCTS  The Consumer Product Safety Commission has said: “Keep
                                                                         ®
           windows only under the sill at the side jambs to lift it off the rough   The exterior of some Andersen products may be painted or   children away from open windows to prevent falls. Don’t
           sill. Shims also enable a straight frame for proper weatherstrip   stained. However, improper painting and staining may cause   depend on insect screens to keep the child from falling out
           contact and unit operation. If not placed properly, unit      damage to vinyl, aluminum and other exterior materials.   of the window. They are designed to keep insects out, not
           performance and operation can be affected. Use waterproof shims          children in. Avoid placing furniture near windows to keep
           capable of supporting the weight of the product. When using   CAUTIONS   children from climbing to a window seat or sill.” In an effort
           tapered shims, use them in pairs with the tapers opposing each   1. Do not apply any type of film to insulating glass. Thermal   to educate consumers about the potential for child falls from
           other to avoid tilting the unit or twisting (rotating) of the jambs.   stress and glass damage can result. Andersen Corporation   windows, Andersen Corporation created the LookOut For Kids
                                                                                    Program. It combines a window and door safety brochure
                                                is not responsible for product performance when films are
           SEALANTS                             applied to Andersen products.       and specific product instructions to help make window and
           Sealants are elastic materials used to block the passage of    2. The use of removable insulating materials such as insulated   door safety an important priority for consumers. For more
           water and/or air while allowing movement between the two     window coverings, shutters and other shading devices may   information on child safety, write:
           sides of the joint. A sealant should bond tightly and be able to   also cause thermal stress conditions and/or deformation of   Andersen Corporation
           expand and contract to accommodate joint movement without   protective vinyl. In addition, excessive condensation may   LookOut For Kids   Program
           cracking or tearing away from the substrate. Surfaces must be   result, which can have a deteriorating effect on the window   100 Fourth Avenue North
           clean, dry and sound for adequate sealant adhesion. Choose a   or patio door unit(s) involved. Andersen Corporation is not   Bayport, MN 55003
           sealant that is compatible with, and that will adhere adequately  responsible for product performance when these kinds of   Call: 1-800-313-8889   Email: lofk@andersencorp.com
           • Dimensions in parentheses are in millimeters.