Page 46 - Andersen Architectural Collection E-Series 2017-18 Product Guide for Professionals
P. 46
Push Out Casement Window Sizes
NOTES
1' 6 1 /4" 1' 8 1 /2" 2' 0 1 /2" 2' 4 1 /2" 2' 6 1 /2" 2' 8 1 /2" 3' 0 1 /2" † These units meet or exceed the following
1' 5 3 /4" 1' 8" 2' 0" 2' 4" 2' 6" 2' 8" 3' 0" dimensions: Clear Opening Area 5.7 sq. ft., Clear
R.O. Opening Width 20", Clear Opening Height 24" and
F .S. 44" maximum floor to sill height (with standard
6'10-1/2" structural header height). Local codes
2' 0 1/ 2" 2' 0" may differ. Verify egress requirements with your
local building code official.
PCMT15 3 /4 20 PCMT1820 PCMT2020 PCMT2420 PCMT2620 PCMT2820 PCMT3020
Units ≤ 24" Actual Frame Width (AFW) will receive
2' 6 1/ 2" 2' 6" Units > 24" AFW and ≤ 30" AFW receive clip only.
hinges only (no clip or friction arm).
PCMT15 3 /4 26 PCMT1826 PCMT2026 PCMT2426 PCMT2626 PCMT2826 PCMT3026 Units > 30" AFW receive (2) 14" friction arms.
2' 8 1/ 2" 2' 8" If glass is positioned within 18" of the finished floor,
safety/tempered glass may be required. Local codes
may differ. Verify tempered glass requirements with
your local building code official.
PCMT15 3 /4 28 PCMT1828 PCMT2028 PCMT2428 PCMT2628 PCMT2828 PCMT3028
3' 0 1/ 2" 3' 0" Use structural joining material when necessary or
required by code.
The light patterns illustrated apply to rectangular
PCMT15 3 /4 30 PCMT1830 PCMT2030 PCMT2430 PCMT2630 PCMT2830 PCMT3030 removable interior wood grilles, Full Divided Light,
3' 4 1/ 2" 3' 4" Simulated Divided Light, Decorelle 100, 150 and 400
™
and Finelight Grilles-Between-the-Glass. All removable
interior wood grilles will be installed in the units
unless otherwise specified.
PCMT15 3 /4 34 PCMT1834 PCMT2034 PCMT2434 PCMT2634 PCMT2834 PCMT3034
For a metric conversion in millimeters, multiply
4' 0 1/ 2" 4' 0" dimensions in inches by 25.4.
Vent Layout as Viewed From Exterior
PCMT15 3 /4 40 PCMT1840 PCMT2040 PCMT2440 PCMT2640 PCMT2840 PCMT3040 †
4' 6 1/ 2" 4' 6"
PCMT15 3 /4 46 PCMT1846 PCMT2046 PCMT2446 PCMT2646 PCMT2846 PCMT3046 †
Left Stationary Right
5' 0 1/ 2" 5' 0"
FORMULA FOR COMBINATION WINDOWS
The overall frame dimension (both width and height)
PCMT15 3 /4 50 PCMT1850 PCMT2050 PCMT2450 PCMT2650 PCMT2850 PCMT3050 † is equal to the sum of the individual unit frame
dimensions plus joining material dimension(s).
5' 6 1/ 2" 5' 6" The overall rough opening (both width and height) is
equal to the overall frame dimensions plus 1/4" on
all sides.
Any unit within each combination can be operating
or stationary.
PCMT15 3 /4 56 PCMT1856 PCMT2056 PCMT2456 PCMT2656 PCMT2856 PCMT3056 †
6' 0 1/ 2" 6' 0"
PCMT15 /4 60 PCMT1860 PCMT2060 PCMT2460 PCMT2660 PCMT2860 PCMT3060 †
3
2- Wide 3-Wide 4-Wide 5-Wide
Joined
Casement
Combinations
Single Unit Rough Frame Rough Frame Rough Frame Rough Frame
Frame Width Opening Width Width Opening Width Width Opening Width Width Opening Width Width
1'-5 3/4" 3'-0" 2'-11 1/2" 4'-5 3/4" 4'-5 1/4" 5'-11 1/2" 5'-11" 7'-5 1/4" 7'-4 3/4"
1'-8" 3'-4 1/2" 3'-4" 5'-0 1/2" 5'-0" 6'-8 1/2" 6'-8" 8'-4 1/2" 8'-4"
2'-0" 4'-0 1/2" 4'-0" 6'-0 1/2" 6'-0" 8'-0 1/2" 8'-0" 10'-0 1/2" 10'-0"
2'-4" 4'-8 1/2" 4'-8" 7'-0 1/2" 7'-0" 9'-4 1/2" 9'-4" 11'-8 1/2" 11'-8"
2'-6" 5'-0 1/2" 5'-0" 7'-6 1/2" 7'-6" 10'-0 1/2" 10'-0" 12'-6 1/2" 12'-6"
2'-8" 5'-4 1/2" 5'-4" 8'-0 1/2" 8'-0" 10'-8 1/2" 10'-8" 13'-4 1/2" 13'-4"
3'-0" 6'-0 1/2" 6'-0" 9'-0 1/2" 9'-0" 12'-0 1/2" 12'-0" 15'-0 1/2" 15'-0"
44 FOR WINDOWS OVER 30 SQUARE FEET OR RATED HIGHER THAN PG50, ONE OF THESE THREE INSTALLATION METHODS IS REQUIRED:
A) THROUGH THE JAMB B) ALUMINUM NAILING FLANGE OR C) INSTALLATION CLIPS.
ADDITIONAL CUSTOM SIZES ARE AVAILABLE. CONTACT YOUR LOCAL SUPPLIER FOR MORE INFORMATION. DRAWINGS ARE NOT TO SCALE.