Page 45 - Andersen Architectural Collection E-Series 2017-18 Product Guide for Professionals
P. 45
French Casement Window Sizes
1
1
3' 4 /2" 4' 0 1 /2" 4' 8 /2" 5' 0 /2" Vent Layout as Viewed From Exterior Casement Windows
1
3' 4" 4' 0" 4' 8" 5' 0" E-Series
R.O.
F .S.
3' 0 1/ 2" 3' 0" Left Sash Opens First
FCMT3430 FCMT4030 FCMT4830 FCMT5030 (Standard Con guration)
3' 4 1/ 2" 3' 4" NOTES
† These units meet or exceed the following dimensions:
Clear Opening Area 5.7 sq. ft., Clear Opening Width
FCMT3434 FCMT4034 FCMT4834 FCMT5034 20", Clear Opening Height 24" and 44" maximum
floor to sill height (with standard 6'10-1/2" structural
4' 0 1/ 2" 4' 0" header height). Local codes may differ. Verify egress
requirements with your local building code official.
Piano hinges and step jamb are standard on all French
FCMT3440 † FCMT4040 † FCMT4840 † FCMT5040 † casement units.
If glass is positioned within 18" of the finished floor, safety/
4' 6 1/ 2" 4' 6" tempered glass may be required. Local codes may differ.
Verify tempered glass requirements with your local building
code official.
FCMT3446 † FCMT4046 † FCMT4846 † FCMT5046 † Use structural joining material when necessary or required
by code.
5' 0 1/ 2" 5' 0" The light patterns illustrated apply to rectangular removable
interior wood grilles, Full Divided Light, Simulated Divided
Light, Decorelle 100, 150 and 400 and Finelight Grilles-
™
Between-the-Glass. All removable interior wood grilles will be
FCMT3450 † FCMT4050 † FCMT4850 † FCMT5050 † installed in the units unless otherwise specified.
For a metric conversion in millimeters, multiply dimensions
in inches by 25.4.
FORMULA FOR COMBINATION WINDOWS
The overall frame dimension (both width and height) is equal
to the sum of the individual unit frame dimensions plus
joining material dimension(s).
The overall rough opening (both width and height) is equal to
the overall frame dimensions plus 1/4" on all sides.
Any unit within each combination can be operating or
stationary.
FOR WINDOWS OVER 30 SQUARE FEET OR RATED HIGHER THAN PG50, ONE OF THESE THREE INSTALLATION METHODS IS REQUIRED: 43
A) THROUGH THE JAMB B) ALUMINUM NAILING FLANGE OR C) INSTALLATION CLIPS.
ADDITIONAL CUSTOM SIZES ARE AVAILABLE. CONTACT YOUR LOCAL SUPPLIER FOR MORE INFORMATION. DRAWINGS ARE NOT TO SCALE.