Page 239 - Andersen Architectural Collection A-Series 2018-19 Product Guide for Professionals
P. 239

TECHNICAL DATA




           GENERAL NOTES                        of the sealant. A general rule of thumb is that the depth of      applied to or used in conjunction with Andersen products.
           When ordering, make certain you specify, then verify, the exact   the sealant joint should be equal to half the width (D= W/2),   3.  In wall construction utilizing brick facades, leave
           product, unit dimensions, configuration requirements, color and   but generally not less than  ⁄4" (6) or more than  ⁄2" (13).      adequate clearance between sill, jambs and brick for
                                                                          1
                                                              1
           options you desire on each window or patio door. Before   Foam-plastic backer rod can be used to limit the depth            sealing and dimensional change of framework.
           installing the product, we suggest you verify that it includes the   of the sealant joint, to provide a backstop for tooling the   4.   Acid solutions commonly used to wash brick and other
           features and options you ordered. Visit andersenwindows.com   sealant without damage to the bond. It also acts as a bond      masonry materials will damage glass, fasteners,
           for product installation and joining guides. Printing limitations   breaker to help minimize stress in the sealant. Sealants      hardware and metal flashing. Protect unit and follow
           prohibit exact color duplication of products. View actual   should be maintained seasonally and repaired and/or      cleaning product instructions carefully. Damage caused
           samples for building specifications. Andersen Corporation   replaced as needed.     by acid solution is not covered under the Andersen
           reserves the right to change details, specifications or sizes               limited warranty.
           without notice. The customer assumes all risk of alterations   GENERAL INSTALLATION GUIDELINES  5.   Andersen windows may be combined in almost
           made to Andersen  products.           1.  Read and follow the installation guide in its entirety.      unlimited ribbons or stacks if each unit is positively
                     ®
                                                 2.  Decide whether you are integrating to a surface barrier or a      secured to structural elements on opposing sides and
           CODES                                  membrane drainage system before installing the product.      if the proper joining system is used. See page 206 for
           Appropriate selection of Andersen products that conform to      The appropriate method for your installation may vary based
           all applicable laws, ordinances, building codes and safety   on building design, application and industry practices.     more information.
           requirements is the sole responsibility of the architect,     3.  Make certain the drainage plane is continuous (proper   SAFETY GLASS
           designer, building owner and/or contractor. Check with your   overlaps to shed water, taped seams, etc.).  Unless specifically ordered, Andersenwindows are not

           local building code officials for specific information. Unit wind    4.  Andersen products should be installed only in the vertical   made with safety glass and, if broken, the glass could
           load, performance grade and energy performance information    position.  fragment, causing injury. Andersen windows may be
           is provided on pages 206-233. For up-to-date product                     ordered with tempered glass which may reduce the
           performance information, visit andersenwindows.com. The    5.  Check the rough opening to make sure it is sized properly,     likelihood of injury when broken. All Andersen patio doors
           performance of any building system depends on the design and   is square and is level.  are made with tempered glass. Differences in appearance
           construction of the building system in its entirety, which should    6.  Install the window plumb.  between tempered and non-tempered glass can be
           meet building code requirements, as well as address product    7.  Install the window level.  expected. Slight visual distortions may be noticeable
           and material limitations and local environment and climate.   8.  Install the window square. Diagonal measurements should   and occur normally as a result of the tempering process.
                                                  be within  ⁄ 8" (3).              Building codes require safety glass in locations adjacent
                                                       1
           DRIP CAPS                             9.   Follow installation instructions to properly locate shims and
           Drip caps are a specific type of flashing or trim that is used at   to make sure that units are plumb, level and square. Shims   to or near doors and other locations.
           the head of a window or door to direct water from the drainage   are always required under the window jambs at the sill and   WINDOW AND PATIO DOOR SAFETY
           plane out beyond the face of the unit.                                   Windows may provide a secondary avenue of escape or
                                                  along the jambs on the sides.
                                                                                    rescue in an emergency, such as a fire. Every family should
           FLASHING                              10. Check for squareness of unit before final anchoring of the
           Flashing is an important element in a building’s water   product into the wall.  develop an escape plan and make sure family members
           management system. It is used to shed and direct water to          11. Anchor window as directed with appropriate fasteners.  know how to escape from the home in an emergency. In
                                                                                    your plan, include two ways to escape from every room in
           the building exterior or to the drainage plane. Flashing materials   12.  Integrate the window into the drainage plane of the wall
           are typically applied starting from the bottom and working   using quality flashing and sealing materials. All flashing   case one way is blocked by fire or smoke, and make sure
           upward, with each successive layer overlapping the previous   materials should be properly overlapped to shed water.  you have a designated meeting place outside. A window
           one in shingle fashion. Water infiltration problems in any type     13. Allow  ⁄ 4" (6) minimum space for a sealant joint around   or a door is an alternate means of escape or rescue.
                                                     1
           of building can be reduced by properly flashing and/or sealing   perimeter of unit between exterior finish materials and unit.  Practice your plan until each member of the family
           around all building openings, including windows and doors.               understands it and is able to escape without assistance.
                                                 14. Insulate and seal the interior cavity between the window   Remember, you may not be able to reach children during
           USE OF SHIMS                           frame and the rough opening.      a fire emergency. Teach children – even very young
           Shims are used along the side jambs of windows and doors to    15. Check unit operation before application of interior trim.  children – that they must escape from a fire in the home
           center the unit in the rough opening and to position it plumb, level   16. Stain and/or seal all unfinished wood surfaces promptly     and never hide from the fire or from emergency personnel.
           and square. In addition, shims are always required for windows   to minimize moisture absorption.  ®
           only under the sill at the side jambs to lift it off the sill plate.     LOOKOUT FOR KIDS  PROGRAM
                                                                                    The Consumer Product Safety Commission has said: “Keep
           Shims also enable a straight frame for proper weatherstrip contact  EXTERIOR PAINTING/SEALING OF ANDERSEN  PRODUCTS  children away from open windows to prevent falls. Don’t
                                                                         ®
           and unit operation. If not placed properly, unit performance and   The exterior of some Andersen products may be painted or
           operation can be affected. Use waterproof shims capable of   stained. However, improper painting and staining may cause   depend on insect screens to keep the child from falling out
           supporting the weight of the product. When using tapered shims,   damage to vinyl, aluminum and other exterior materials.   of the window. They are designed to keep insects out, not
           use them in pairs with the tapers opposing each other to avoid           children in. Avoid placing furniture near windows to keep
           tilting the unit or twisting (rotating) of the jambs.   CAUTIONS         children from climbing to a window seat or sill.” In an effort
                                                 1.  Do not apply any type of film to insulating glass. Thermal    to educate consumers about the potential for child falls
           SEALANTS                                stress and glass damage can result. Andersen Corporation         from windows, Andersen Corporation created the LookOut
           Sealants are elastic materials used to block the passage of      is not responsible for product performance when films are    For Kids Program. It combines a window and door safety
           water and/or air while allowing movement between the two      applied to Andersen products.  brochure and specific product instructions to help make
           sides of the joint. A sealant should bond tightly and be able to   2.   The use of removable insulating materials such as    window and door safety an important priority for consumers.
           expand and contract to accommodate joint movement without      insulated window coverings, shutters and other shading    For more information on child safety, write:
           cracking or tearing away from the substrate. Surfaces must be      devices may also cause thermal stress conditions and/or
           clean, dry and sound for adequate sealant adhesion. Choose a      deformation of protective vinyl. In addition, excessive    Andersen Corporation

           sealant that is compatible with, and that will adhere adequately     condensation may result, which can have a deteriorating    LookOut For Kids Program
           to, all building materials used in the window and patio door      effect on the window or patio door unit(s) involved.    100 Fourth Avenue North
           area. Proper sealant joint design is based upon the expected      Andersen Corporation is not responsible for product    Bayport, MN 55003  Combination Designs,   Product Performance
           movement of adjacent materials and the movement capability      performance when these kinds of materials or devices are    Call: 1-800-313-8889 Email: lofk@andersencorp.com  & Installation
           Dimensions in parentheses are in millimeters.