TECHNICAL DATA
GENERAL NOTES of the sealant. A general rule of thumb is that the depth of applied to or used in conjunction with Andersen products.
When ordering, make certain you specify, then verify, the exact the sealant joint should be equal to half the width (D= W/2), 3. In wall construction utilizing brick facades, leave
product, unit dimensions, configuration requirements, color and but generally not less than ⁄4" (6) or more than ⁄2" (13). adequate clearance between sill, jambs and brick for
1
1
options you desire on each window or patio door. Before Foam-plastic backer rod can be used to limit the depth sealing and dimensional change of framework.
installing the product, we suggest you verify that it includes the of the sealant joint, to provide a backstop for tooling the 4. Acid solutions commonly used to wash brick and other
features and options you ordered. Visit andersenwindows.com sealant without damage to the bond. It also acts as a bond masonry materials will damage glass, fasteners,
for product installation and joining guides. Printing limitations breaker to help minimize stress in the sealant. Sealants hardware and metal flashing. Protect unit and follow
prohibit exact color duplication of products. View actual should be maintained seasonally and repaired and/or cleaning product instructions carefully. Damage caused
samples for building specifications. Andersen Corporation replaced as needed. by acid solution is not covered under the Andersen
reserves the right to change details, specifications or sizes limited warranty.
without notice. The customer assumes all risk of alterations GENERAL INSTALLATION GUIDELINES 5. Andersen windows may be combined in almost
made to Andersen products. 1. Read and follow the installation guide in its entirety. unlimited ribbons or stacks if each unit is positively
®
2. Decide whether you are integrating to a surface barrier or a secured to structural elements on opposing sides and
CODES membrane drainage system before installing the product. if the proper joining system is used. See page 206 for
Appropriate selection of Andersen products that conform to The appropriate method for your installation may vary based
all applicable laws, ordinances, building codes and safety on building design, application and industry practices. more information.
requirements is the sole responsibility of the architect, 3. Make certain the drainage plane is continuous (proper SAFETY GLASS
designer, building owner and/or contractor. Check with your overlaps to shed water, taped seams, etc.). Unless specifically ordered, Andersenwindows are not
local building code officials for specific information. Unit wind 4. Andersen products should be installed only in the vertical made with safety glass and, if broken, the glass could
load, performance grade and energy performance information position. fragment, causing injury. Andersen windows may be
is provided on pages 206-233. For up-to-date product ordered with tempered glass which may reduce the
performance information, visit andersenwindows.com. The 5. Check the rough opening to make sure it is sized properly, likelihood of injury when broken. All Andersen patio doors
performance of any building system depends on the design and is square and is level. are made with tempered glass. Differences in appearance
construction of the building system in its entirety, which should 6. Install the window plumb. between tempered and non-tempered glass can be
meet building code requirements, as well as address product 7. Install the window level. expected. Slight visual distortions may be noticeable
and material limitations and local environment and climate. 8. Install the window square. Diagonal measurements should and occur normally as a result of the tempering process.
be within ⁄ 8" (3). Building codes require safety glass in locations adjacent
1
DRIP CAPS 9. Follow installation instructions to properly locate shims and
Drip caps are a specific type of flashing or trim that is used at to make sure that units are plumb, level and square. Shims to or near doors and other locations.
the head of a window or door to direct water from the drainage are always required under the window jambs at the sill and WINDOW AND PATIO DOOR SAFETY
plane out beyond the face of the unit. Windows may provide a secondary avenue of escape or
along the jambs on the sides.
rescue in an emergency, such as a fire. Every family should
FLASHING 10. Check for squareness of unit before final anchoring of the
Flashing is an important element in a building’s water product into the wall. develop an escape plan and make sure family members
management system. It is used to shed and direct water to 11. Anchor window as directed with appropriate fasteners. know how to escape from the home in an emergency. In
your plan, include two ways to escape from every room in
the building exterior or to the drainage plane. Flashing materials 12. Integrate the window into the drainage plane of the wall
are typically applied starting from the bottom and working using quality flashing and sealing materials. All flashing case one way is blocked by fire or smoke, and make sure
upward, with each successive layer overlapping the previous materials should be properly overlapped to shed water. you have a designated meeting place outside. A window
one in shingle fashion. Water infiltration problems in any type 13. Allow ⁄ 4" (6) minimum space for a sealant joint around or a door is an alternate means of escape or rescue.
1
of building can be reduced by properly flashing and/or sealing perimeter of unit between exterior finish materials and unit. Practice your plan until each member of the family
around all building openings, including windows and doors. understands it and is able to escape without assistance.
14. Insulate and seal the interior cavity between the window Remember, you may not be able to reach children during
USE OF SHIMS frame and the rough opening. a fire emergency. Teach children – even very young
Shims are used along the side jambs of windows and doors to 15. Check unit operation before application of interior trim. children – that they must escape from a fire in the home
center the unit in the rough opening and to position it plumb, level 16. Stain and/or seal all unfinished wood surfaces promptly and never hide from the fire or from emergency personnel.
and square. In addition, shims are always required for windows to minimize moisture absorption. ®
only under the sill at the side jambs to lift it off the sill plate. LOOKOUT FOR KIDS PROGRAM
The Consumer Product Safety Commission has said: “Keep
Shims also enable a straight frame for proper weatherstrip contact EXTERIOR PAINTING/SEALING OF ANDERSEN PRODUCTS children away from open windows to prevent falls. Don’t
®
and unit operation. If not placed properly, unit performance and The exterior of some Andersen products may be painted or
operation can be affected. Use waterproof shims capable of stained. However, improper painting and staining may cause depend on insect screens to keep the child from falling out
supporting the weight of the product. When using tapered shims, damage to vinyl, aluminum and other exterior materials. of the window. They are designed to keep insects out, not
use them in pairs with the tapers opposing each other to avoid children in. Avoid placing furniture near windows to keep
tilting the unit or twisting (rotating) of the jambs. CAUTIONS children from climbing to a window seat or sill.” In an effort
1. Do not apply any type of film to insulating glass. Thermal to educate consumers about the potential for child falls
SEALANTS stress and glass damage can result. Andersen Corporation from windows, Andersen Corporation created the LookOut
Sealants are elastic materials used to block the passage of is not responsible for product performance when films are For Kids Program. It combines a window and door safety
water and/or air while allowing movement between the two applied to Andersen products. brochure and specific product instructions to help make
sides of the joint. A sealant should bond tightly and be able to 2. The use of removable insulating materials such as window and door safety an important priority for consumers.
expand and contract to accommodate joint movement without insulated window coverings, shutters and other shading For more information on child safety, write:
cracking or tearing away from the substrate. Surfaces must be devices may also cause thermal stress conditions and/or
clean, dry and sound for adequate sealant adhesion. Choose a deformation of protective vinyl. In addition, excessive Andersen Corporation
sealant that is compatible with, and that will adhere adequately condensation may result, which can have a deteriorating LookOut For Kids Program
to, all building materials used in the window and patio door effect on the window or patio door unit(s) involved. 100 Fourth Avenue North
area. Proper sealant joint design is based upon the expected Andersen Corporation is not responsible for product Bayport, MN 55003 Combination Designs, Product Performance
movement of adjacent materials and the movement capability performance when these kinds of materials or devices are Call: 1-800-313-8889 Email: lofk@andersencorp.com & Installation