TECHNICAL DATA
®
Andersen NFRC Certified Total Unit Performance — Dual-Pane Glass (continued)
For current performance information, please visit andersenwindows.com.
®
®
Andersen Product High-Performance Dual-Pane Glass Type U-Factor 1 SHGC 2 VT 3 Andersen Product High-Performance Dual-Pane Glass Type U-Factor 1 SHGC 2 VT 3
Without Grilles 0.31 0.29 0.49 Without Grilles 0.35 0.19 0.30
Low-E4 ® Simulated Divided Light Grilles 0.31 0.26 0.43 Low-E4 ® Simulated Divided Light Grilles 0.35 0.15 0.22
0.16
0.36
0.26
0.31
0.26
Finelight ™ Grilles
0.43
Finelight ™ Grilles
Full Divided Light Grilles 0.32 0.26 0.43 Full Divided Light Grilles 0.36 0.15 0.22
Without Grilles 0.28 0.28 0.48 Without Grilles - - -
Low-E4 ® w/HeatLock ® Simulated Divided Light Grilles 0.28 0.25 0.42 Low-E4 ® w/HeatLock ® Simulated Divided Light Grilles - - - - - -
0.28
Finelight ™ Grilles
0.25
0.42
Finelight ™ Grilles
-
-
-
0.29
0.26
Without Grilles
Residential/Commercial Full Divided Light Grilles 0.30 0.25 0.42 Commercial Outswing Full Divided Light Grilles 0.35 0.12 0.17
Without Grilles
0.17
Outswing Entry Door Simulated Divided Light Grilles 0.29 0.15 0.23 Entry Door Sidelights* Simulated Divided Light Grilles 0.35 0.10 0.12
Transom* Low-E4 ® Sun Rectangular Low-E4 ® Sun
Sash-Set Finelight ™ Grilles 0.31 0.16 0.24 AND-N-144 Finelight ™ Grilles 0.36 0.11 0.14
AND-N-130 Full Divided Light Grilles 0.30 0.15 0.23 Full Divided Light Grilles 0.36 0.10 0.12
Without Grilles 0.31 0.19 0.44 Without Grilles 0.34 0.13 0.27
Low-E4 ® SmartSun ™ Simulated Divided Light Grilles 0.31 0.17 0.39 Low-E4 ® SmartSun ™ Simulated Divided Light Grilles 0.34 0.10 0.20
Finelight ™ Grilles
Finelight ™ Grilles
0.31
0.35
0.39
0.11
0.23
0.17
Full Divided Light Grilles 0.32 0.17 0.39 Full Divided Light Grilles 0.35 0.10 0.20
Without Grilles 0.27 0.19 0.43 Without Grilles - - -
Low-E4 ® SmartSun ™ w/HeatLock ® Simulated Divided Light Grilles 0.27 0.17 0.38 Low-E4 ® SmartSun ™ w/HeatLock ® Simulated Divided Light Grilles - - - - - -
Finelight ™ Grilles
Finelight ™ Grilles
0.38
0.27
0.17
Full Divided Light Grilles
0.34
0.19
0.31
Without Grilles 0.29 0.18 0.38 Full Divided Light Grilles - - -
Low-E4 ® Simulated Divided Light Grilles 0.34 0.15 0.24
0.35
Finelight ™ Grilles
0.27
0.17
Full Divided Light Grilles 0.35 0.15 0.24
Without Grilles - - -
Low-E4 ® w/HeatLock ® Simulated Divided Light Grilles - - - - - -
Finelight ™ Grilles
Full Divided Light Grilles - - -
Residential Outswing Without Grilles 0.34 0.12 0.17
Entry Door Sidelights* Simulated Divided Light Grilles 0.34 0.10 0.13
Arch & Rectangular Low-E4 ® Sun
AND-N-136 Finelight ™ Grilles 0.35 0.11 0.15
Full Divided Light Grilles 0.35 0.10 0.13
Without Grilles 0.33 0.13 0.28
Low-E4 ® SmartSun ™ Simulated Divided Light Grilles 0.33 0.11 0.21
0.25
0.12
0.34
Finelight ™ Grilles
Full Divided Light Grilles 0.34 0.11 0.21
Without Grilles - - -
Low-E4 ® SmartSun ™ w/HeatLock ® Simulated Divided Light Grilles - - - - -
Finelight ™ Grilles
-
-
Full Divided Light Grilles
-
Without Grilles 0.33 0.21 0.35
Low-E4 ® Simulated Divided Light Grilles 0.33 0.16 0.24
0.29
Finelight ™ Grilles
0.18
0.35
Full Divided Light Grilles 0.34 0.16 0.24
Without Grilles - - -
Low-E4 ® w/HeatLock ® Simulated Divided Light Grilles - - - - - -
Finelight ™ Grilles
-
-
Full Divided Light Grilles
-
Without Grilles 0.34 0.13 0.19
Commercial Rectangular Simulated Divided Light Grilles 0.34 0.10 0.14
Outswing Entry Door* Low-E4 ® Sun
AND-N-139 Finelight ™ Grilles 0.35 0.12 0.16
Full Divided Light Grilles 0.35 0.10 0.14
Without Grilles 0.33 0.15 0.31 • "Low-E4 ® ", "Low-E4 ® SmartSun ™ ", "Low-E4 ® Sun" and HeatLock ® are Andersen trademarks for "Low-E" glass.
2
1) U-Factor defines the amount of heat loss through the total unit in BTU/hr/ft .°F. The lower the value, the less
Low-E4 ® SmartSun ™ Simulated Divided Light Grilles 0.33 0.11 0.22 heat is lost through the entire product. Window values represent non-tempered glass. Use of tempered glass
0.13
0.34
Finelight ™ Grilles
can increase U-Factor ratings. See andersenwindows.com/nfrc for specific performance values. Door values
0.26
Full Divided Light Grilles 0.34 0.11 0.22 represent tempered glass. 2) Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation
admitted through the glass both directly transmitted and absorbed and subsequently released inward. The
Without Grilles - - - lower the value, the less heat is transmitted through the product. 3) Visible Transmittance (VT) measures how
Low-E4 ® SmartSun ™ w/HeatLock ® Simulated Divided Light Grilles - - - - - - much light comes through a product (glass and frame). The higher the value, from 0 to 1, the more daylight the
product lets in over the product’s total unit area. Visible Transmittance is measured over the 380 to 760
Finelight ™ Grilles
nanometer portion of the solar spectrum.
Full Divided Light Grilles - - - • NFRC ratings are based on modeling by a third-party agency as validated by an independent test lab in
compliance with NFRC program and procedural requirements.
• This data is accurate as of January 2018. Due to ongoing product changes, updated test results or new
industry standards or requirements, this data may change over time. Ratings are for sizes specified by NFRC
for testing and certification. Ratings may vary depending on unit size, use of tempered glass, different grille
options, glass for high altitudes, etc.
• Values are for single units with given pane thickness and 3 / 4 " (19mm) grilles for windows and 1" (25mm)
grilles for door products.
*Ratings for product with 4 3 / 4 " (121mm) stile widths. Ratings for Springline ™ entry doors and additional stile widths
can be found at andersenwindows.com/nfrc. Combination Designs, Product Performance
229 & Installation