Page 93 - Andersen Windows & Patio Doors 2017-18 100 Series Product Guide for Professionals
P. 93

TECHNICAL DATA




         PREFORMANCE STANDARDS                                   HALLMARK CERTIFICATION
         The Window and Door Manufacturers Association (WDMA), the American Architectural   The Window and Door Manufacturers Association (WDMA) sponsored Hallmark Certification
         Manufacturers Association (AAMA) and the Canadian Standards Association (CSA) jointly release   Program provides manufacturers with certification to the AAMA/WDMA/CSA 101/I.S.2/A440-11
         the North American Fenestration Standard/Specification for Windows, Doors and Skylights   Standard and is designed to provide builders, architects, specifiers and consumers with an
         (NAFS-11) where "-11" refers to the most recent publication year of 2011. NAFS is also referred to    easily recognizable means of identifying products that have been manufactured and tested
         as AAMA/WDMA/CSA 101/I.S.2/A440, which is how the International Code Council (ICC) lists this   in accordance with NAFS (AAMA/WDMA/CSA 101/I.S.2/A440) industry standards and other
         standard in the 2012 and 2015 International Residential Code (IRC) and International Building   applicable performance standards. Conformance is determined by periodic in-plant
         Code (IBC) as the means to indicate the window, door or skylights design pressure rating used to   inspections by a third-party administrator. Inspections include auditing licensee quality
         determine compliance to the jobsite design pressure requirements.   control procedures and processes, and a review to confirm products are manufactured in
         A product only achieves a “Performance Grade” or “PG” rating when it complies with all of the    accordance with the appropriate performance standards. Periodic testing of representative
         NAFS performance requirements such as ease of operation, air infiltration resistance, resistance to   product constructions and components by an independent testing laboratory is also required.
         water penetration and resistance to forced entry, etc.. A “Design Pressure Rating” or “DP” rating   When all of the program requirements are met, the licensee is authorized to use the
         only depicts the design and structural load performance.  WDMA Hallmark registered logo on their Certification Label as a means of identifying
         Performance Classes                                     products and their performance ratings.
         The NAFS Standard/Specification defines requirements for four performance classes. Performance   Products successfully obtaining Hallmark Certification will be labeled with a 3-part code,
         classes are designated R, LC, CW, and AW. This classification system provides for several levels   which includes performance class, performance grade and size tested. In addition to this
         of performance. Product selection is always based on the performance and building code    mandatory requirement you are allowed to list the design pressure on a separate line.
         requirements of the particular project.
         Elements of Performance Grade (PG) Designations
         In order to qualify for a given performance grade (PG), test specimens need to pass all required   Andersen Corporation
                                                                                         100 SERIES CASEMENT WINDOW
         performance tests for the following, in addition to all required auxiliary (durability) and applicable   Hallmark Certified   Manufacturer stipulates certification as indicated below.
         material/component tests (not shown here) for the applicable product type and desired   www.wdma.com
         performance class:                                            STANDARD                   RATING
                                                                                       CLASS LC (1)  – PG40 (2)  – SIZE TESTED 71.5 X 71.5 in. (3)
         (a) Operating force (if applicable):  Maximum operating force vary by product type and   AAMA/WDMA/CSA 101/I.S.2/A440-11  DP+40/-45 (4)
         performance class.                                       AAMA/WDMA/CSA 101/I.S.2/A440-08  CLASS LC (1)  – PG40 (2)  – SIZE TESTED 71.5 X 71.5 in. (3)
         (b) Air leakage resistance:  Tested in accordance with ASTM E283 at a test pressure of 1.57 psf.  DP+40/-45 (4)
         Allowable air infiltration for R, LC and CW class designations is 0.3 cubic feet per minute per
         square foot of frame (cfm/ft ).                         (1) – Performance Class
                        2
         (c) Water penetration resistance:  Tested in accordance with ASTM E547 with the specified test   (2) – Performance Grade
         pressure applied per NAFS-11. Test consists of four cycles. Each cycle consists of five minutes   (3) – Size Tested
         with pressure applied and one minute with the pressure released, during which the water spray is   (4) – Design Pressure
         continuously applied. Water spray shall be uniformly applied at a constant rate of 5 U.S. gal/ft  • hr.   In the example above, the performance class is LC, the performance grade (PG) is 40 pounds
                                                          2
         (d) Uniform load deflection test:  Tested in accordance with ASTM E330 for both positive   per square foot (psf) and the size tested is 71.5" x 71.5". What this means to the specifier is,
         and negative pressure (pressure defined by NAFS-11) with the load maintained for a period of  based on the performance grade chart, the laboratory tested air infiltration was less than
         10 seconds. The test specimen shall be evaluated for deflection during each load, for permanent   0.3 cfm/ft  (test pressure is always 1.57 psf and the allowable airflow is 0.3 cfm/ft ), the        Combination Designs,   Product Performance,   Installation & Warranty
                                                                       2
                                                                                                             2
         damage after each load and for any effects on the normal operation of the specimen. Starting   product tested successfully resisted a laboratory water penetration test at a test pressure
         with the 2008 version of NAFS, design pressure (DP) will only represent the "uniform load   of 6.0 psf, the product tested successfully withstood a laboratory positive test pressure of
         deflection test".                                       60 psf, a laboratory negative test pressure of 67 psf and the product tested passed the
         (e) Uniform load structural test:  Tested in accordance with ASTM E330 for both positive and   laboratory requirements for operational force and forced entry resistance. Based on this
         negative pressure (pressure defined by NAFS-11) with the load maintained for a period of 10   test, all products smaller in both width and height can be labeled with this product
         seconds. After loads are removed there shall be no permanent deformation in excess of 0.4%   performance rating.
         of its span and no damage to the unit, which would make it inoperable.
         (f) Forced-entry resistance (if applicable):  Tested in accordance with ASTM F588 (windows),   IMPORTANT
         F476 (swinging doors) and F842 (sliding doors) at a performance level 10 rating.
                                                                 Building codes prescribe design pressure based on a variety of criteria (i.e. windspeed
         Performance Grades (PG) & Corresponding Test Pressures (psf)  zone, building height, building type, jobsite exposure, etc.). Design pressures derived from
          Performance      Maximum                               Performance Grade (PG) test requirements should be used to determine compliance to
           Class/  Air Infiltration   Allowable Air   Water Penetration   Structual Test
          Performance   Test Pressure  Infiltration/  Resistance Test   Design Pressure  Pressure  building code required design pressures. Structural test pressures, which are tested at
            Grade         Exfiltration Rate  Pressure
                                                                 1.5 times the design pressure, should not be used for determining design pressure code
           R  LC  Pa  psf  L/s·m 2 cfm/ft 2  Pa  psf  Pa  psf  Pa  psf  compliance. In the example above, a PG 40 performance grade rating, which passes a
          15  -   75  1.57  1.5  0.30  140  2.92  720  15.04  1080  22.56
          20  -   75  1.57  1.5  0.30  150  3.13  960  20.05  1440  30.08  40 psf design pressure, should be used for determining code compliance, not the structural
          25  25  75  1.57  1.5  0.30  180  3.76  1200  25.06  1800  37.59  test pressure of 60 psf.
          30  30  75  1.57  1.5  0.30  220  4.59  1440  30.08  2160  45.11
          35  35  75  1.57  1.5  0.30  260  5.43  1680  35.09  2520  52.63  If you need further details about how Andersen® products perform to this standard,
          40  40  75  1.57  1.5  0.30  290  6.06  1920  40.10  2880  60.15
          45  45  75  1.57  1.5  0.30  330  6.89  2160  45.11  3240  67.67  contact your Andersen supplier.
          50  50  75  1.57  1.5  0.30  360  7.52  2400  50.13  3600  75.19  If you need further information about the AAMA/WDMA/CSA 101/I.S.2/A440-11 standard
          55  55  75  1.57  1.5  0.30  400  8.35  2640  55.14  3960  82.71
          60  60  75  1.57  1.5  0.30  440  9.19  2880  60.15  4320  90.23  or the Hallmark Certification Program please contact:  WDMA, 330 N. Wabash Avenue
          65  65  75  1.57  1.5  0.30  470  9.82  3120  65.16  4680  97.74
          70  70  75  1.57  1.5  0.30  510  10.65  3360  70.18  5040  105.26  Suite 2000, Chicago, IL 60611   Phone:  312-673-4828   Web:  wdma.com
          75  75  75  1.57  1.5  0.30  540  11.28  3600  75.19  5400  112.78  Where designated, Andersen products are tested, certified and labeled to the requirements
          80  80  75  1.57  1.5  0.30  580  12.11  3840  80.20  5760  120.30
          85  85  75  1.57  1.5  0.30  580  12.11  4080  85.21  6120  127.82  of the Hallmark Certification Program. Actual performance may vary based on variations
          90  90  75  1.57  1.5  0.30  580  12.11  4320  90.23  6480  135.34  in manufacturing, shipping, installation, environmental conditions and conditions of use.
          95  95  75  1.57  1.5  0.30  580  12.11  4560  95.24  6840  142.86
          100  100  75  1.57  1.5  0.30  580  12.11  4800  100.25  7200  150.38